IMS IndustrieMontageService GmbH Logo

Medical Technology

Precision assembly for highest quality standards

In medical technology, precision and reliability are not an option, but a duty. Our specialists assemble medical technology components and devices under the strictest quality requirements.

Our Expertise

Highest Quality Standards

Assembly according to medical technology standards with complete documentation

Precise Assemblies

Assembly of delicate medical components with microscopic accuracy

Hygienic Manufacturing

Clean production environment and appropriate processes

Applications

Diagnostic devices
Medical sensors
Surgical instruments
Laboratory equipment
Patient monitoring
Therapy devices

Our Medical Technology Competencies

Cleanroom Assembly

ISO 14644-1 Class 8 (formerly Class 100,000). Applications: diagnostic sensors, optical components, disposable catheter components, laboratory automation. Cleanroom protocol includes airlock with protective clothing, HEPA filters with 99.995% efficiency, daily disinfection wipes, weekly particle counting.

✓ Your advantage: No contamination of sensitive medical components, validated cleanliness through regular controls

Batch Traceability & Documentation

Complete traceability for complaints or recalls. System: incoming goods with internal batch numbers, assembly documentation with signatures, delivery notes with batch IDs. Retention: electronic unlimited, paper 10 years per MDR.

✓ Your advantage: Every assembly traceable down to individual component, MDR-compliant documentation

Delicate Sensor and Optics Assembly

Handling: antistatic tweezers, vacuum suction, microscope-assisted work. Work environment: ESD protection per DIN EN 61340, cleanroom, air-conditioned. Quality control: 100% optical inspection with microscope, functional testing, ESD bag packaging.

✓ Your advantage: Safe assembly of sensitive sensors without damage, consistent quality

ISO 13485 Understanding

IMS is not ISO 13485 certified, but works in accordance with ISO 9001. Working method: documented work instructions with version control, batch traceability, 100% incoming goods inspection, complaint management with 8D reports. Suitable for: prototypes, clinical studies, non-invasive devices Class I/IIa.

✓ Your advantage: Quality according to medical technology principles without certification costs for prototype phase

Typical Medical Technology Projects

Prototypes for Clinical Studies

Description: Development of a new diagnostic device. 50-200 functional samples needed for clinical study – close to series, but not yet final.

Requirements: Fast availability, GCP-compliant documentation, iterative adjustments based on study feedback

Solution: Phase 1: Prototype assembly (10-30 pieces) with express service in 48-72h, cleanroom assembly, photo documentation. Phase 2: Integrate study feedback, implement design changes. Phase 3: Final study batch (50-200 pieces) with near-series quality.

Case Study:

A medical technology startup developed a sensor system for continuous glucose monitoring. Over 18 months we assembled 4 batches (50-100 pieces each) for clinical studies. Each batch integrated learnings. After CE certification: transition to series production at IMS (5,000 pieces/year).

Sensor Assemblies for Diagnostics

Description: Laboratory automation, point-of-care diagnostics, blood analysis. Optical sensors (photodiodes, LEDs), electrochemical sensors (pH, oxygen, glucose), pressure sensors, temperature sensors for thermocyclers.

Challenges: Calibration (often by customer after assembly), reproducible assembly (sensor position affects measurement), cleanliness (contamination can falsify measurement)

Solution: Assembly in cleanroom, position fixtures for reproducible placement, functional pre-testing (basic signal, offset), individual packaging in ESD bags.

Case Study:

We assembled 1,000 photodiode arrays for a blood analyzer. Each unit was tested for basic signal (dark current). 99.6% passed pre-testing. Customer calibrated in their own laboratory.

Housing Assemblies for Handheld Devices

Description: Patient monitoring, point-of-care diagnostics, therapy devices. Display units with touchscreen, housing integration of electronics and battery, buttons and controls.

Requirements: Robustness (drops in clinical environment), tightness (liquid protection IP54+), hygiene (wipe-disinfectable)

Solution: Precision assembly with tight tolerances (< 0.5mm gap), seal integration (O-rings, flat gaskets), functional testing, optional drop test.

Case Study:

We assembled 500 handheld diagnostic devices for infectious disease detection. Housing from aluminum die-cast with plastic cover, display, electronics, battery. Functional test with customer software. Delivery time: 6 weeks.

Disposable Components for Consumables

Description: Infusion systems, dialysis, catheters, laboratory automation. Syringe assemblies, tube systems with Luer-Lock connectors, filter units, sample tubes.

Requirements: High quantities (often 10,000+), low unit costs (disposable), sterility (post-assembly sterilization by customer)

Solution: IMS is ideal for pre-series and ramp-up phase (100-5,000 pieces). For larger series, recommendation for automation.

Case Study:

A customer developed a disposable infusion set. We assembled pre-series (500 pieces) for approval tests. After CE approval: customer switched to automated production. We continue to deliver express batches during supply shortages.

Why IMS for Your Medical Technology Assembly?

ISO 13485 Understanding (even without certificate)

We know the requirements of regulated markets: documented processes, batch traceability, validation of critical process steps, complaint management. Advantage: Even without certification, we work according to standards that your regulatory department accepts.

Fast Prototypes for Clinical Studies

Time-to-market is critical. Our express service starts in 48h – ideal for study start deadlines, iterative development with physician feedback, approval tests. Example: A customer needed 30 prototypes for FDA submission in 10 days. We delivered after 8 days – approval was not delayed.

Confidentiality & NDA as Standard

Medical technology development is highly confidential. Our measures: NDA before project start, separated assembly areas, no mention in references without consent.

Cleanroom & ESD Protection

Essential for medical sensors and electronics: Cleanroom ISO Class 8, ESD protection per DIN EN 61340, calibrated measuring and testing equipment.

Regional Proximity to Medical Technology Hubs

Rhine-Main area: Mainz (BioNTech, pharma cluster), Frankfurt (medical technology startups, university hospital), Darmstadt (Merck, pharma research). Your advantage: short distances for coordination, fast prototype pickup, personal on-site meetings.

Frequently Asked Questions (FAQ)

Are you ISO 13485 certified?

No, IMS is not ISO 13485 certified, but works in accordance with ISO 9001. We work according to many principles that ISO 13485 also requires: documented work instructions, batch traceability, 100% quality control, complaint management (CAPA). Suitable for: prototypes and clinical studies (before CE approval), components for medical devices (if end customer is ISO 13485 certified), non-invasive devices Class I/IIa. Not suitable for: implants, invasive devices Class III, IVD Class D. Recommendation: Check with your regulatory department if our processes are sufficient.

Can you sterilize assemblies?

No, we do not offer sterilization. We assemble in a clean environment (cleanroom), but we do not achieve sterility. Options: You sterilize after assembly (gamma, ETO, autoclaving) or we work with sterilization service providers (we deliver there, you pick up sterilized goods). Important: clarify before assembly whether your assembly can tolerate the sterilization process (e.g., temperature during autoclaving).

How do you document for MDR/FDA approvals?

We create documentation that you can use for approval documents. Standard: work instructions with version number, test protocols with measured values, batch traceability, delivery notes with batch IDs. Extended (on request): First Article Inspection Report (FAIR/FAI), process FMEA, validation protocol for critical process steps, certificates for materials used (RoHS, REACH, biocompatibility). Important: we do not create approval documents (that is the task of your regulatory department), but we provide the data you need for it.

Which medical technology classes can you serve?

Our processes are suitable for: MDR Class I (low risk) - non-invasive devices such as blood pressure monitors, thermometers. MDR Class IIa (medium risk) - short-term invasive devices such as catheters, diagnostic devices without critical function. MDR Class IIb (elevated risk) - with restrictions, depending on customer requirements, recommendation for clarification with regulatory department. MDR Class III (highest risk) - not recommended, requires ISO 13485 certified service provider. IVD (in-vitro diagnostics): Class A/B suitable, Class C/D with restrictions.

What does medical technology assembly cost?

Medical technology projects have higher quality requirements. Surcharges: cleanroom assembly +20-30%, extended documentation +10-20%, 100% functional test +15-25%. Typical costs: Simple sensor assembly (cleanroom, 30 min.): €80-150 per piece (for 10-50 pieces), €50-100 (for 100-500 pieces). Housing assembly with electronics (cleanroom, 2h): €250-500 per piece (for 10-50 pieces), €150-300 (for 100-500 pieces). Plus: process development (€500-2,000), validation (€1,000-3,000).

Can you also handle software validation?

No, we are not a software service provider. What we do: programming of microcontrollers (firmware flash), functional test with your software, documentation of the software version we flashed. What we don't do: software development, software validation according to IEC 62304, cybersecurity assessment. Recommendation: work with specialized software service provider for validation.

How do you handle patient data?

We do not process patient data. We assemble devices that later process patient data – but there is no contact during assembly. If there is (e.g., during functional testing with patient simulator): data anonymization, data protection according to GDPR, deletion after project completion.

Ready for Precision Assembly?

Contact us for a non-binding consultation about your project.